Define a rotary-drying project from wet feed to the required discharge moisture, including the heat source and exhaust-handling arrangement.
Select the image for a closer look.
Project selection
Provide incoming moisture variation, material characteristics and the intended product condition. Ask for a complete proposed heat and material balance and identify the fuel or heat source being considered. Review feed handling, discharge cooling if required, gas treatment and storage interfaces so the quotation covers more than the rotating drum.
Before comparing purchase prices, define the complete equipment boundary and the work required at the Australian site. Request current model documentation, an arrangement drawing and an itemised equipment list. Include transport access and available site services so technical selection, delivery planning and installation can be discussed using one consistent project brief.
Use the enquiry form to share details of your material properties, wet-feed rate, moisture targets and preferred heat source. Add your site location, project stage and preferred timing. If you are still gathering technical information, tell us what you have so far. We can help identify what is needed for the next assessment.
The details that matter
| Diameter × length (mm) | Volume (m³) | Capacity (t/h) | Gradient (%) | Highest inlet air temperature (°C) | Rotation speed (r/min) | Main motor (kW) |
|---|---|---|---|---|---|---|
| Φ600x6000 | 1.7 | 0.5-1.5 | 3~5 | 700~800 | 3~8 | 3 |
| Φ800x8000 | 4.1 | 0.8-2.0 | 3~5 | 700~800 | 3~8 | 4 |
| Φ800x10000 | 5.1 | 0.8-2.5 | 3~5 | 700~800 | 3~8 | 4 |
| Φ1000x10000 | 7.9 | 1.0-3.0 | 3~5 | 700~800 | 3~8 | 7.5 |
| Φ1000x12000 | 9.4 | 1.2-3.2 | 3~5 | 700~800 | 3~8 | 11 |
| Φ1200x8000 | 9 | 1.9-2.4 | 3~5 | 700~800 | 3~8 | 7.5 |
| Φ1200x10000 | 11.3 | 2.2-3.0 | 3~5 | 700~800 | 3~8 | 7.5 |
| Φ1200x12000 | 13.6 | 2.4-3.2 | 3~5 | 700~800 | 3~8 | 7.5 |
| Φ1500x12000 | 21.2 | 4.5-5.7 | 3~5 | 700~800 | 2~6 | 15 |
| Φ1500x14000 | 24.7 | 5.3-6.6 | 3~5 | 700~800 | 2~6 | 15 |
| Φ1500x16000 | 26.5 | 5.7-7.1 | 3~5 | 700~800 | 2~6 | 15 |
| Φ1800x12000 | 30.5 | 6.5-8.1 | 3~5 | 700~800 | 2~6 | 18.5 |
| Φ1800x14000 | 35.6 | 7.6-9.5 | 3~5 | 700~800 | 2~6 | 18.5 |
| Φ1800x16000 | 40.7 | 7.8-10.2 | 3~5 | 700~800 | 2~6 | 18.5 |
| Φ2000x18000 | 56.5 | 8.4-12.3 | 3~5 | 700~800 | 1.5~6 | 22 |
| Φ2000x20000 | 62.8 | 9.0-13.6 | 3~5 | 700~800 | 1.5~6 | 22 |
| Φ2200x16000 | 60.8 | 11.4-15.8 | 3~5 | 700~800 | 1.5~6 | 22 |
| Φ2200x18000 | 68.3 | 12.8-16.2 | 3~5 | 700~800 | 1.5~6 | 22 |
| Φ2200x20000 | 75.9 | 13.0-16.5 | 3~5 | 700~800 | 1.5~6 | 30 |
| Φ2400x16000 | 72.3 | 13.5-16.9 | 3~5 | 700~800 | 1.5~5 | 37 |
| Φ2400x18000 | 81.4 | 17.4-21.7 | 3~5 | 700~800 | 1.5~5 | 45 |
| Φ2400x20000 | 90.4 | 19.3-24.1 | 3~5 | 700~800 | 1.5~5 | 55 |
| Φ2600x24000 | 127.4 | 27.2-34.0 | 3~5 | 700~800 | 1.5~5 | 75 |
| Φ2600x28000 | 148.6 | 28.6-36.2 | 3~5 | 700~800 | 1.5~5 | 75 |
| Φ3000x20000 | 141.3 | 30.1-37.7 | 3~5 | 700~800 | 1.5~5 | 85 |
| Φ3000x25000 | 176.6 | 37.7-47.1 | 3~5 | 700~800 | 1.5~5 | 90 |
| Φ3200x25000 | 201 | 42.9-53.6 | 3~5 | 700~800 | 1.5~5 | 110 |
| Request a quote for your model | ||||||
Specifications are based on published manufacturer information. Capacity depends on material and configuration. The downloadable PDF is a website summary; request current manufacturer drawings and the configured supply scope before ordering.
Supply both incoming and required outgoing moisture, together with material and operating conditions. Ask for the duty basis used in each offer so the drying task is comparable.
Request scope details for feeding, heating, air movement, exhaust treatment and product discharge. Clarify any cooling, storage, fuel services and installation work required outside the quoted package.
Across Australia
Equipment enquiries for Perth, Brisbane, Sydney, Melbourne, Adelaide, Hobart, Darwin, Canberra and regional project locations. Tell us where your site is so freight, access and installation requirements can be assessed.

Western Australia (WA)
Albany, Bunbury, Busselton, Geraldton, Kalgoorlie–Boulder, Karratha, Mandurah, Port Hedland, Broome

Queensland (QLD)
Cairns, Gold Coast, Sunshine Coast, Townsville, Toowoomba, Mackay, Rockhampton, Bundaberg, Gladstone, Mount Isa, Hervey Bay, Ipswich

New South Wales (NSW)
Newcastle, Wollongong, Albury, Armidale, Bathurst, Broken Hill, Coffs Harbour, Dubbo, Goulburn, Griffith, Lismore, Orange, Port Macquarie, Tamworth, Wagga Wagga

Victoria (VIC)
Geelong, Ballarat, Bendigo, Mildura, Shepparton, Warrnambool, Wodonga, Wangaratta, Latrobe Valley

South Australia (SA)
Mount Gambier, Whyalla, Port Augusta, Port Lincoln, Port Pirie, Murray Bridge

Tasmania (TAS)
Launceston, Devonport, Burnie

Northern Territory (NT)
Alice Springs, Katherine, Palmerston, Tennant Creek

Australian Capital Territory (ACT)
Canberra region
Delivery, availability and service scope are confirmed for each quotation.
Your next project starts here
Your equipment is already selected when you enquire from a product page. Add your contact details and a short message, and we can work through the requirements with you.
01 / Select your equipment
02 / Tell us what you need
03 / Discuss your project