
Perth
Western Australia (WA)
Regional project locations
Albany, Bunbury, Busselton, Geraldton, Kalgoorlie–Boulder, Karratha, Mandurah, Port Hedland, Broome
Mining & quarry equipment / Australia
Compare a single-cylinder hydraulic cone configuration using the prepared feed, target aggregate sizes and proposed control arrangement.
Select the image for a closer look.
Project selection
Define the duty before comparing hydraulic layouts. Ask for the exact DG or other quoted model, chamber and ancillary package, and how the operating settings will be monitored. Consider where the lubrication and hydraulic equipment will be located and how their services connect to the wider crushing circuit.
Include the Australian site and receiving arrangements when submitting the technical brief. Ask the supplier to identify equipment, auxiliaries, interfaces and purchaser-supplied services in one written proposal. Review the current drawings against available space and material flow, then resolve model-specific questions before treating a preliminary configuration as the final equipment specification.
Use the enquiry form to share details of your primary-stage output, target screen cuts, existing controls and installation footprint. Add your site location, project stage and preferred timing. If you are still gathering technical information, tell us what you have so far. We can help identify what is needed for the next assessment.
The details that matter
| Model | Cavity Type | Max Feeding Size(mm) | Adjusting Range of Discharge Opening (mm) | Capacity (t/h) | Power (kw) | Enquire |
|---|---|---|---|---|---|---|
| CH420 (DG100) | Extra Coarse - EC | 155 | 10-32 | 46-128 | 90 | Request quoteCH420 (DG100) |
| Confirm with manufacturer | Coarse - C | 103 | 10-32 | 13-118 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium - M | 76 | 8-19 | 36-80 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium Fine - MF | 58 | 6-16 | 36-71 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Fine - F | 42 | 4-16 | 27-57 | Confirm with manufacturer | Confirm model first |
| CH430 (DG200) | Extra Coarse - EC | 185 | 13-38 | 69-208 | 160 | Request quoteCH430 (DG200) |
| Confirm with manufacturer | Coarse - C | 150 | 13-38 | 66-197 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium - M | 101 | 10-32 | 64-162 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium Fine - MF | 86 | 8-25 | 61-126 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Fine - F | 62 | 6-25 | 48-103 | Confirm with manufacturer | Confirm model first |
| CH440 (DG300) | Extra Coarse - EC | 220 | 16-44 | 114-395 | 220 | Request quoteCH440 (DG300) |
| Confirm with manufacturer | Coarse - C | 175 | 13-44 | Confirm with manufacturer | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium - M | 157 | 13-38 | 97-328 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium Fine - MF | 125 | 13-38 | 114-299 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Fine - F | 80 | 8-32 | 90-251 | Confirm with manufacturer | Confirm model first |
| CH660 (DG500) | Extra Coarse - EC | 321 | 16-51 | 177-662 | 315 | Request quoteCH660 (DG500) |
| Confirm with manufacturer | Coarse - C | 253 | 16-51 | 171-643 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium Coarse - MC | 198 | 16-44 | 162-552 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium - MF | 155 | 16-38 | 197-502 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Medium Fine - MF | 133 | 13-38 | 192-451 | Confirm with manufacturer | Confirm model first |
| Confirm with manufacturer | Fine - F | 96 | 13-38 | Confirm with manufacturer | Confirm with manufacturer | Confirm model first |
| Request a quote for your model | ||||||
| Model | Cavity Type | Max Feeding Size(mm) | Adjusting Range of Discharge Opening (mm) | Capacity (t/h) | Power (kw) | Enquire |
|---|---|---|---|---|---|---|
| CH420 (DG100S) | Extra Coarse - EC | 267 | 22-38 | 85-168 | 160 | Request quoteCH420 (DG100S) |
| Confirm with manufacturer | Coarse - C | 223 | Confirm with manufacturer | 170-280 | Confirm with manufacturer | Confirm model first |
| CHS430 (DG200S) | Extra Coarse - EC | 320 | 25-54 | 126-344 | 160 | Request quoteCHS430 (DG200S) |
| Confirm with manufacturer | Coarse - C | 260 | 19-48 | 108-301 | Confirm with manufacturer | Confirm model first |
| CHS440 (DG300S) | Extra Coarse - EC | 400 | 29-51 | 267-601 | 250 | Request quoteCHS440 (DG300S) |
| Confirm with manufacturer | Coarse - C | 350 | 25-51 | 225-511 | Confirm with manufacturer | Confirm model first |
| CHS660 (DG500S) | Extra Coarse - EC | 622 | 41-83 | 349-1050 | 315 | Request quoteCHS660 (DG500S) |
| Confirm with manufacturer | Coarse - C | 556 | 38-70 | 318-892 | Confirm with manufacturer | Confirm model first |
| Request a quote for your model | ||||||
Specifications that need clarification are marked for confirmation or omitted. Request the current datasheet for your selected model and configuration.
Specifications are based on published manufacturer information. Capacity depends on material and configuration. The downloadable PDF is a website summary; request current manufacturer drawings and the configured supply scope before ordering.
They may refer to the same offered product family. Confirm the supplier's exact model designation and datasheet; one verified configuration should drive the specification and procurement comparison.
Identify the upstream feeder and downstream screen, then ask what monitoring, alarms and interlocks are included. Request an interface list for connection to existing plant controls.
Across Australia
Equipment enquiries for Perth, Brisbane, Sydney, Melbourne, Adelaide, Hobart, Darwin, Canberra and regional project locations. Tell us where your site is so freight, access and installation requirements can be assessed.

Western Australia (WA)
Albany, Bunbury, Busselton, Geraldton, Kalgoorlie–Boulder, Karratha, Mandurah, Port Hedland, Broome

Queensland (QLD)
Cairns, Gold Coast, Sunshine Coast, Townsville, Toowoomba, Mackay, Rockhampton, Bundaberg, Gladstone, Mount Isa, Hervey Bay, Ipswich

New South Wales (NSW)
Newcastle, Wollongong, Albury, Armidale, Bathurst, Broken Hill, Coffs Harbour, Dubbo, Goulburn, Griffith, Lismore, Orange, Port Macquarie, Tamworth, Wagga Wagga

Victoria (VIC)
Geelong, Ballarat, Bendigo, Mildura, Shepparton, Warrnambool, Wodonga, Wangaratta, Latrobe Valley

South Australia (SA)
Mount Gambier, Whyalla, Port Augusta, Port Lincoln, Port Pirie, Murray Bridge

Tasmania (TAS)
Launceston, Devonport, Burnie

Northern Territory (NT)
Alice Springs, Katherine, Palmerston, Tennant Creek

Australian Capital Territory (ACT)
Canberra region
Delivery, availability and service scope are confirmed for each quotation.
Your next project starts here
Your equipment is already selected when you enquire from a product page. Add your contact details and a short message, and we can work through the requirements with you.
01 / Select your equipment
02 / Tell us what you need
03 / Discuss your project