Skip to content
Mining & quarry machinery for Australian projects
AboutResourcesSupport
BAICHY.

Mining & quarry equipment / Australia

Trommel Screen in Australia

Assess a trommel-screen arrangement through the feed material, required separations and the handling of oversize and undersize streams.

Baichy Trommel Screen

Select the image for a closer look.

Project selection

Choose the right configuration.

Describe variable, sticky or irregular feed in practical terms and provide photographs or samples. Ask which drum and aperture arrangement is proposed and how the material will enter and leave it. Check access for cleaning and media inspection, particularly where the screening unit must fit into an established material-handling area.

For an Australian project, include the site location and delivery access in the technical brief. Request a written scope identifying the proposed configuration, installation interfaces and services required from the purchaser. Compare quotations against the same duty, and ask for current drawings and datasheets that match the exact equipment being offered.

Use the enquiry form to share details of your feed samples or photos, separation sizes, moisture variation and collection layout. Add your site location, project stage and preferred timing. If you are still gathering technical information, tell us what you have so far. We can help identify what is needed for the next assessment.

Before you request a quote

  • Feed variability and sticking observations
  • Drum aperture and separation objective
  • Cleaning access and discharge collection

The details that matter

Compare models. Specify with confidence.

Trommel Screen | model specifications
ModelDrum Diameter (mm)Drum Length (mm)Max feeding size (mm)Capacity (t/h)Power (kw)Enquire
GT101510001500<30010-154Request quoteGT1015
GT102010002000<30015-255.5Request quoteGT1020
GT122512002500<30025-407.5Request quoteGT1225
GT153015003000<30060-8011Request quoteGT1530
GT154515004500<30080-15015Request quoteGT1545
GT184818004800<300150-20022Request quoteGT1848
GT186018006000<300160-22018.5Request quoteGT1860
GT205520005500<300200-26030Request quoteGT2055
GT258025008000<300300-60022×2Request quoteGT2580
Request a quote for your model

Specifications are based on published manufacturer information. Capacity depends on material and configuration. The downloadable PDF is a website summary; request current manufacturer drawings and the configured supply scope before ordering.

Download specification PDF

Questions about Trommel Screen

How should trommel and vibrating-screen options be compared?

Provide the same feed description and required separations to each assessment. Ask for material-specific proposals covering feed presentation, screening arrangement, installation space and expected maintenance tasks.

What should a difficult-feed enquiry include?

Send photographs, particle-size information, moisture observations and examples of contaminants. State the required products and ask what sample testing or feed preparation is needed.

Across Australia

Your project. Your part of Australia.

Equipment enquiries for Perth, Brisbane, Sydney, Melbourne, Adelaide, Hobart, Darwin, Canberra and regional project locations. Tell us where your site is so freight, access and installation requirements can be assessed.

Western Australia (WA) stylised icon

Perth

Western Australia (WA)

Regional project locations

Albany, Bunbury, Busselton, Geraldton, Kalgoorlie–Boulder, Karratha, Mandurah, Port Hedland, Broome

Queensland (QLD) stylised icon

Brisbane

Queensland (QLD)

Regional project locations

Cairns, Gold Coast, Sunshine Coast, Townsville, Toowoomba, Mackay, Rockhampton, Bundaberg, Gladstone, Mount Isa, Hervey Bay, Ipswich

New South Wales (NSW) stylised icon

Sydney

New South Wales (NSW)

Regional project locations

Newcastle, Wollongong, Albury, Armidale, Bathurst, Broken Hill, Coffs Harbour, Dubbo, Goulburn, Griffith, Lismore, Orange, Port Macquarie, Tamworth, Wagga Wagga

Victoria (VIC) stylised icon

Melbourne

Victoria (VIC)

Regional project locations

Geelong, Ballarat, Bendigo, Mildura, Shepparton, Warrnambool, Wodonga, Wangaratta, Latrobe Valley

South Australia (SA) stylised icon

Adelaide

South Australia (SA)

Regional project locations

Mount Gambier, Whyalla, Port Augusta, Port Lincoln, Port Pirie, Murray Bridge

Tasmania (TAS) stylised icon

Hobart

Tasmania (TAS)

Regional project locations

Launceston, Devonport, Burnie

Northern Territory (NT) stylised icon

Darwin

Northern Territory (NT)

Regional project locations

Alice Springs, Katherine, Palmerston, Tennant Creek

Australian Capital Territory (ACT) stylised icon

Canberra

Australian Capital Territory (ACT)

Regional project locations

Canberra region

Delivery, availability and service scope are confirmed for each quotation.

Explore the same equipment family

Bulk material conveying

6 configurations

Baichy Belt Conveyor

Belt Conveyor

Aggregate sizing

27 published models

Baichy YK Vibrating Screen

YK Vibrating Screen

Primary plant feeding

8 published models

Baichy ZSW Vibrating Feeder

ZSW Vibrating Feeder

Your next project starts here

Tell us about your project.

Your equipment is already selected when you enquire from a product page. Add your contact details and a short message, and we can work through the requirements with you.

01 / Select your equipment

02 / Tell us what you need

03 / Discuss your project

By sending this enquiry, you agree to be contacted about your request. Privacy notice

Project enquiry

Request a quote

By sending this enquiry, you agree to be contacted about your request. Privacy notice

Image detail

Zoom, then drag to inspect. Use + / - to zoom, arrow keys to pan, and Esc to close.

Keep your team in the loop

Share this page

BAICHY

Choose your language

Choose the language you would like to use.

You can change your language at any time using the menu.