
Perth
Western Australia (WA)
Regional project locations
Albany, Bunbury, Busselton, Geraldton, Kalgoorlie–Boulder, Karratha, Mandurah, Port Hedland, Broome
Mining & quarry equipment / Australia
Assess VSI crushing for a defined manufactured-sand or shaping duty, using prepared feed and the intended grading as the basis.
Select the image for a closer look.
Project selection
Ask the supplier to explain the proposed crushing arrangement and the material assumptions behind it. Map the upstream screen, recirculating stream and final product treatment before comparing machines. Where the customer requires a particular sand specification, include test results and a proposed verification method in the enquiry.
Bring the operating layout into the enquiry early. For an Australian installation, identify the site location, access constraints and available services, then request drawings for the exact proposed configuration. Ask for the equipment supply, purchaser responsibilities and installation interfaces to be listed clearly so competing proposals can be assessed against the same requirement.
Use the enquiry form to share details of your prepared feed data, intended sand use, grading specification and available downstream equipment. Add your site location, project stage and preferred timing. If you are still gathering technical information, tell us what you have so far. We can help identify what is needed for the next assessment.
The details that matter
| Model | VSI-7611 | VSI-8518 | VSI-9526 | VSI-1140 | VSI-1145 |
|---|---|---|---|---|---|
| Capacity (t/h) | Cascade and Center Feeding | 120-180 | 200-260 | 300-360 | 450-520 | 500-600 |
| Capacity (t/h) | Center Feeding | 60-90 | 100-130 | 150-190 | 225-260 | 250-360 |
| Feeding Size (mm) | Soft Material | < 35 | < 40 | < 45 | < 50 | < 50 |
| Feeding Size (mm) | Hard Material | < 30 | < 35 | < 40 | < 45 | < 45 |
| Rotation Speed (r/min) | 1700-1890 | 1520-1690 | 1360-1510 | 1180-1310 | 1180-1280 |
| Power of the Double Motors (kw) | 2x55 | 2x90 | 2x132 | 2x200 | 2x220 |
| Overall dimension L*W*H (mm) | 4100×2290×2350 | 4600×2280×2650 | 4600×2350×2850 | 5200×2600×3220 | 5500×2790×3320 |
| Select your model | Request quoteVSI-7611 | Request quoteVSI-8518 | Request quoteVSI-9526 | Request quoteVSI-1140 | Request quoteVSI-1145 |
| Parameter | Manufacturer specification |
|---|---|
| Power source | 380 V; 50 Hz |
| Vibrating sensor | Inspection scope: 0.1–20 mm/s; continuously adjustable |
| Hydraulic lubrication station | double oil-pump power | 2 × 0.31 kW |
| Hydraulic lubrication station | safety | Dual oil pumps; automatic stop on loss of oil flow or pressure; water cooling; winter motor heating start |
| Hydraulic lubrication station | overall L×W×H (mm) | 820×520×1270 |
| Oil-box heater power | 2 kW |
| Request a quote for your model | |
Specifications that need clarification are marked for confirmation or omitted. Request the current datasheet for your selected model and configuration.
Specifications are based on published manufacturer information. Capacity depends on material and configuration. The downloadable PDF is a website summary; request current manufacturer drawings and the configured supply scope before ordering.
Provide the actual size distribution for assessment. Ask the supplier to identify required upstream crushing and screening rather than assuming the VSI accepts unprepared quarry feed.
The required grading and material properties must be assessed for the complete circuit. Request sample testing and a product verification plan covering crushing, classification and any washing stages.
Across Australia
Equipment enquiries for Perth, Brisbane, Sydney, Melbourne, Adelaide, Hobart, Darwin, Canberra and regional project locations. Tell us where your site is so freight, access and installation requirements can be assessed.

Western Australia (WA)
Albany, Bunbury, Busselton, Geraldton, Kalgoorlie–Boulder, Karratha, Mandurah, Port Hedland, Broome

Queensland (QLD)
Cairns, Gold Coast, Sunshine Coast, Townsville, Toowoomba, Mackay, Rockhampton, Bundaberg, Gladstone, Mount Isa, Hervey Bay, Ipswich

New South Wales (NSW)
Newcastle, Wollongong, Albury, Armidale, Bathurst, Broken Hill, Coffs Harbour, Dubbo, Goulburn, Griffith, Lismore, Orange, Port Macquarie, Tamworth, Wagga Wagga

Victoria (VIC)
Geelong, Ballarat, Bendigo, Mildura, Shepparton, Warrnambool, Wodonga, Wangaratta, Latrobe Valley

South Australia (SA)
Mount Gambier, Whyalla, Port Augusta, Port Lincoln, Port Pirie, Murray Bridge

Tasmania (TAS)
Launceston, Devonport, Burnie

Northern Territory (NT)
Alice Springs, Katherine, Palmerston, Tennant Creek

Australian Capital Territory (ACT)
Canberra region
Delivery, availability and service scope are confirmed for each quotation.
Fine aggregate crushing
8 published models
Vertical compound reduction
6 published models
Your next project starts here
Your equipment is already selected when you enquire from a product page. Add your contact details and a short message, and we can work through the requirements with you.
01 / Select your equipment
02 / Tell us what you need
03 / Discuss your project